Ground fault monitor

INTRODUCTION

This manual describes how to install this Whole Home Ground Fault Monitor,

CurrentLeak

TM

in a single phase service entrance combination panel. These

instructions do not cover all details or variations of service entrances, if you

require more information regarding a particular application that is not covered in

this manual, please contact a licensed/qualified electrical contractor.

WHEN INSTALLED ACCORDING TO THIS MANUAL, this product will provide

a visual display of the ground fault level in your entire electrical system. This

product will not prevent ground faults from occurring or prevent electrical fires

related to ground faults. In order to prevent electrical fires related to ground

faults, it is the sole responsibility of the end user to ensure their electrical

system is and remains free of all ground faults at all times.

THIS PRODUCT WILL NOT monitor and display ground fault levels in electrical

systems that are not grounded and/or do not have grounded branch circuits

and/or is not installed in accordance to the instructions in this manual. If you

have questions or require assistance, contact a licensed/qualified electrical

contractor.

THIS MANUAL PROVIDES PROCEDURES to isolate branch circuits that

contain ground faults, a licensed/qualified electrician shall repair all ground

faults.

IMPORTANT !

THIS PRODUCT SHALL BE INSTALLED by a licensed/qualified electrician in

accordance to the instructions in this manual, Canadian Electrical Code (CEC)

or National Electrical Code (NEC) or other applicable county codes, and any

applicable local codes. All applicable electrical codes supersede these

instructions.

THIS INSTALLATION REQUIRES REMOVING AND REPLACING the factory

installed neutral bond in the service entrance panel. Some jurisdictions may

have special requirements to permit the removal and replacement of a factory

installed neutral bond.

If you have questions or require assistance, contact a licensed/qualified

electrical contractor or the electrical authority in your jurisdiction.

WARNING! SHOCK HAZARDS

Improper installation and/or wiring can cause death, injury and/or

equipment damage.

Follow warnings and cautions. Completely read and understand the information

in this manual before attempting to install or operate this product. Only

licensed/qualified electricians who are trained in the installation and service of

electrical devices shall install and/or service this equipment.

KEEP THESE INSTRUCTIONS FOR FUTURE USE

©

Pivotal Product Developments - All Rights Reserved

PARTS DESCRIPTION

CurrentLeak

TM

monitor

Current transformer

Ethernet cable

9VDC power adaptor

Wire lugs X2

#6 AWG copper bonding cable

Mounting screws X4

Mounting wall anchors X4

SPECIFICATIONS

Patented

WHOLE HOME

INSTALLATION

INSTRUCTIONS

FOR ONTARIO, CANADA ONLY

WHOLE HOME MONITORING REQUIRES REMOVING AND REPLACING the factory installed neutral bond

in the service entrance panel which is permitted in Ontario, Canada, pursuant to the Electrical Safety Authority

(ESA)

Bulletin - Ground Fault Monitoring (2-024, 2-034, 10-210, 10-614 Whole Home Ground Fault Monitoring).

Model number MV1 CTV1

Description CurrentLeak monitor Current transformer

Intended use Indoor use, Max 400A service entrance panel

Operating conditions 5-40°C, 80% max RH at 5-31°C,

decreasing linearly to 50% max RH at 40°C

Altitude Max 2,000m

Input supply voltage 120v, 60Hz 9vDC

Output Voltage 9VDC N/A

Input current 0.132A 0-99mA

Max rated current 0.67A 70.995A

Dimensions W x H x D (mm) 83.8 x 136.4 x 27.9 48 x 95.5 x 38.5

W x H x D (in) 3.3 x 5.37 x 1.1 1.89 x 3.76 x 1.52

Pivotal Product Developments Ltd.

244 Brockport Drive, Unit 12, Toronto, ON M9W 6X9

WARRANTY AND EXCLUSIONS

Pivotal Product Developments Ltd warrants this product for a period of 1 year from the date of delivery to the purchaser to be free from defects in both workmanship and

material. Pivotal Product Developments Ltd assumes no risk or liability for the results of the use of the product purchased from it, including but without limiting the generality of

the foregoing: (1) The use in combination with any electrical or electronic components, circuits, systems, assemblies, or any other materials or substances; (2) Unsuitability of any

product for use in any circuit or assembly. Purchaser's rights under the warranty shall consist solely of requiring Pivotal Product Developments Ltd to repair, or at Pivotal Product

Developments Ltd's sole discretion, replace, free of charge, F.O.B factory, and defective items received at said factory within said term determined by Pivotal Product

Developments Ltd to be defective. The giving of or failure to give any advice or recommendations by Pivotal Product Developments Ltd shall not constitute any warranty by or

impose any liability upon Pivotal Product Developments Ltd.

The foregoing constitutes the sole and exclusive liability of Pivotal Product Developments Ltd AND IS IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESSED, IMPLIED OR

STATUTORY AS TO THE MERCHANTABILITY, FITNESS FOR THE PURPOSE SOLD, DESCRIPTION, QUALITY, PRODUCTIVENESS OR ANY OTHER MATTER. In no event shall Pivotal

Product Developments Ltd be liable for special or consequential damages or for delay in performance of the warranty. This warranty does not apply if the product has been

misused, abused, altered, tampered with, or used in applications other than specified in the manual. At the end of the warranty period, Pivotal Product Developments Ltd shall be

under no further warranty obligation expressed or implied. The product covered by this warranty certificate can only be repaired or replaced by the factory. Repair or

replacement units will be return collected. If Pivotal Product Developments Ltd finds the return to be a manufacturer's defect, the product will be return prepaid.

RETURN POLICY

The purchaser may return the product in it's original packaging, prepaid, within thirty (30) days of the original purchase date for a full refund of the purchase price, not including

freight or shipping charges that may have been paid by the purchaser as part of the original purchase. A copy of the original invoice must be included with the returned product.

Pivotal Product Developments will promptly issue a refund providing that the product is not damaged or in non re-sellable condition. Pivotal Product Developments is under no

obligation to provide a refund if it finds, at it's sole discretion, that the product is damaged or in non re-sellable condition.

Pivotal Product Developments Ltd.

Att: Quality Assurance Department, 244 Brockport Drive, Unit 12 Toronto, Ontario M9W 6X9

pivotal CurrentLeak Whole Home Fire Alarms Installation instructions PDF View/Download (2024)
Top Articles
Latest Posts
Article information

Author: Aron Pacocha

Last Updated:

Views: 5499

Rating: 4.8 / 5 (48 voted)

Reviews: 87% of readers found this page helpful

Author information

Name: Aron Pacocha

Birthday: 1999-08-12

Address: 3808 Moen Corner, Gorczanyport, FL 67364-2074

Phone: +393457723392

Job: Retail Consultant

Hobby: Jewelry making, Cooking, Gaming, Reading, Juggling, Cabaret, Origami

Introduction: My name is Aron Pacocha, I am a happy, tasty, innocent, proud, talented, courageous, magnificent person who loves writing and wants to share my knowledge and understanding with you.